If the website helps you, please consider donating to the site for future quiz takers by buying me coffee.

NBC 2015
Part 9

Top Score Leaderboard

Pos.NameScorePoints
1SAS81 %17
2JD76 %16
3m71 %15
4a71 %15
5AK67 %14
6nick67 %14
7Avi67 %14
8jaja67 %14
9Laleh62 %13
10neetu57 %12
"
/21
20

NBC 2015 - Section 9.4, 9.5, 9.6

Please fill out the form to start the quiz. Good luck!

1 / 21

What is the maximum allowable bearing pressure for dense or compact sand or gravel according to Table 9.4.4.1 of the National Building Code of Canada 2015?

2 / 21

Based on the data in Table 9.6.1.3.-F, what is the maximum glass area for tempered glass with a thickness of 8 mm?

3 / 21

According to the National Building Code of Canada 2015, what is the minimum clear height required in a storage garage?

4 / 21

What is the minimum specified snow load according to the National Building Code of Canada 2015?

5 / 21

According to Table 9.6.1.3.-D, what is the maximum glass area for windows in areas where the 1-in-50 Hourly Wind Pressure (HWP) is less than 0.55 kPa in open terrain, for annealed glass with a thickness of 6 mm?

6 / 21

According to Table 9.6.1.3.-F in the National Building Code of Canada 2015, what is the maximum glass area for annealed glass with a thickness of 5 mm?

7 / 21

According to the National Building Code of Canada 2015, what is the minimum unobstructed width required for a hallway within a dwelling unit?

8 / 21

What is the maximum deflection of the structural roof members according to Article 9.4.3.1?

9 / 21

In what situations should measures be taken to preclude or reduce soil movement that may damage a building's stability and the performance of assemblies?

10 / 21

What information needs to be determined according to Subsection 1.1.3 for structural design?

11 / 21

According to Section 9.4.1.1, what are the three options for designing structural members and their connections?

12 / 21

According to the National Building Code of Canada 2015, what is the minimum width required for a doorway opening in a bathroom?

13 / 21

According to the National Building Code of Canada 2015, what is the maximum deflection ratio for ceiling joists supporting plaster or gypsum board?

14 / 21

According to the National Building Code of Canada 2015, what is the minimum height required for a doorway to a public water-closet room?

15 / 21

According to Table 9.6.1.3.-A, what is the maximum glass area for windows in areas where the 1-in-50 Hourly Wind Pressure (HWP) is less than 0.55 kPa, for annealed glass with a thickness of 6 mm?

16 / 21

Based on the data in Table 9.6.1.3.-F, what is the maximum glass area for heat-strengthened glass with a thickness of 6 mm?

17 / 21

According to the National Building Code of Canada 2015 Volume 2 Division B, how should dimensions of rooms or spaces be measured?

18 / 21

According to Table 9.6.1.3.-B, what is the maximum glass area for windows in areas where the 1-in-50 Hourly Wind Pressure (HWP) is less than 0.75 kPa, for tempered glass with a thickness of 5 mm?

19 / 21

According to the National Building Code of Canada 2015, what is the basic snow load roof factor for roofs where the entire width does not exceed 4.3 m?

20 / 21

What are the requirements for light-frame constructions according to Section 9.4.2.1?

21 / 21

According to the National Building Code of Canada 2015 Volume 2 Division B, how should walls supporting drained earth be designed?

Your score is

The average score is 47%